- Kidde Ionization Smoke Alarm Model I12040a Manual
- Kidde I12060a User Manual
- Kidde Smoke Detector I12020 Chirping
- Kidde Ionization Smoke Alarm Model I12020 User Manual Tool
- Kidde Ionization Smoke Alarm Model I12020
- Kidde Ionization Smoke Alarm Model I12020 User Manual Pdf
Kidde I12020 Smoke Alarm User Manual. Of 2 120V AC Wire-In Smoke Alarm. For Basic Use. Part# 21006374 Model i12020. The Kidde i12020 is an AC powered, ionization. Smoke alarm that operates on a 120V power source. This alarm uses ionization sensing technology. AC Wire-in Single and/or Multiple Station (up to 24 Devices) Ionization Smoke Alarm with HUSH. Control to temporarily silence nuisance alarms. Models i12040A and i12080A have a 9-Volt Battery Back Up and the model i12080A has a battery powered safety light. Thank you for purchasing this smoke alarm. The AC-powered, hardwired Kidde i12040 ionization smoke alarm is designed to protect you and your family from the dangers of smoke and fire. This smoke alarm's trademarked hush feature allows you to silence nuisance alarms, while an indicator LED and test feature let you easily confirm that the alarm is working. User Guide pdf Additional. Your Kidde Smoke Alarm was designed specifically for use in a residential environment. It is not designed for use in a recreational vehicle (RV) or boat. P/N: 0311-7201 RevA For your convenience, write down the following information. If you call Product Support, these are the first questions you will be asked. Smoke Alarm Model Number.
120V AC/DC Wire-in Smoke Alarm
Battery Backup | |
Part Number 21006378 | Model i12040 |
– Ionization Sensing Technology
– One button design (operates Smart Hush™ and test) – Large mounting base
– 9V Battery Backup (included) – Tamper resist feature
– Alarm memory
– Pre-stripped wiring harness with tinned strands
Description
The Kidde i12040 is an AC/DC powered, ionization smoke alarm that operates on a 120V power source with 9V battery backup.
This alarm uses ionization sensing technology. Ionization sensing alarms may detect invisible fire particles (associated with flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible particles (associated with smoldering fires) sooner than ionization alarms.
Kidde strongly recommends that both ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various types of fire that can occur within the home.
This smoke alarm is available in a 6-piece cut case with tray for easy display as well as a 6-piece bulk pack for contractors and property owners. This unit is a UL Listed product with a 10-year limited warranty.
SIGNALING
UL
LISTED
Install Confidence
Easy Installation
•Front battery pull tab allows battery activation without removing alarm from mounting bracket.
•Large mounting base makes mounting easier, protects surface paint from dirt and covers imperfections.
•Pre-stripped wiring harness with easy off cap does not require stripper tool. Tinned strands increase conductivity and wire nut grip.
Fewer Callbacks
•One button design for easy operation and less confusion. Operates Smart Hush™ and alarm test
Kidde Ionization Smoke Alarm Model I12040a Manual
•Battery run down protection will shut down alarm memory when AC power is not present, reducing low battery chirp.
•Dust cover protects sensor from contaminates during construction reducing nuisance alarms
User-Friendly Features
•Tamper resist locking feature deters alarm theft
•Alarm memory flashes red LED indicating which unit was the initiating alarm in interconnected system.
•Interconnectable with up to 24 devices (of which 18 can be initiating) including smoke, CO and heat alarms. See user’s guide for complete instructions.
Technical Specifications
Alarm
Alarms
RED
Part Number 21006378 Model i12040
The smoke alarm must be installed to comply with all local codes having jurisdiction in your area. All wiring shall be in accordance with articles 210 and 300.3(B) of the US National Electrical Code, ANSI / NFPA 70 and NFPA 72. The multiple station interconnect wiring must be in the same raceway as the AC power wiring. In addition the resistance if the interconnect wiring shall be a maximum of 10 ohms. Make certain all alarms are wired to a single, continuous (non-switched) power line, which is not protected by a ground fault interrupter. A maximum of 1000 ft. of wire can be used in the interconnect system. Use standard UL listed household wire as required by code. FUSE OR CIRCUIT BREAKER
Architectural and Engineering
Specifications
Kidde I12060a User Manual
The smoke alarm shall be Kidde model i12040 or approved equal. It shall be powered by a 120VAC, 60Hz source along with a 9V battery backup. The unit shall incorporate an ionization sensor with nominal sensitivity of .50 to
Kidde Smoke Detector I12020 Chirping
.98%ft. The temperature operation range shall be between 40˚F and 100˚F (4˚C and 38˚C) and the humidity operating range shall be 5% - 95% relative humidity.
The smoke alarm can be installed on any standard single gang electrical box, up to a 4” octagon junction box. The electrical connection (to the alarm) shall be made with a plug-in connector. A maximum of 24 Kidde devices can be interconnected in a multiple station arrangement. The interconnect system must not exceed the NFPA (National Fire Protection Association) limit of 18 initiation devices, of which 12 can be smoke alarms. With 18 initiating devices (smoke, heat, CO, etc.), interconnected, it is still possible to interconnect
6 strobe lights and or relay modules. The unit shall provide optional tamper resistance that deters removal of the unit from the wall or ceiling.
The alarm shall include a test button that will electronically simulate the presence of smoke and cause the unit to go into alarm. This sequence tests the unit’s electronics, battery and horn to ensure proper operation.
The unit shall include a piezoelectric horn that is rated at 85 decibels at 10 feet. The unit shall include Smart HushTM feature that silences the unit for approximately 7 minutes if a nuisance condition occurs. The unit shall also include a low battery warning utilizing a brief alarm chirp every 30-40 seconds for a minimum of seven (7) days.
The unit shall incorporate red and green LED indicators. The green LED (when illuminated) indicates the presence of AC power. The red LED (located under the TEST/Hush button) has four modes of operation:
Standby Condition: The red LED will flash every 30-40 seconds to indicate that the smoke alarm is operating properly. Alarm Condition: When the alarm senses products of combustion and goes into alarm the red LED will flash one flash per second. The flashing LED and pulsating alarm will continue until the air is cleared. When units are interconnected, only the red LED of the alarm that senses the smoke or is being tested (the originating unit) will flash. All other units in the interconnected system will sound an alarm but their red LED’s will NOT flash. Alarm Memory: This smoke alarm is equipped with an alarm memory, which provides a visual indication when an alarm has been activated. The red LED will illuminate for about 1.5 seconds every 16 seconds to indicate the memory condition. Smart HushTM Mode: The red LED will illuminate for 1.5 seconds every 8 seconds, indicating the smoke alarm is in the Smart HushTM Mode.
Kidde Ionization Smoke Alarm Model I12020 User Manual Tool
The unit shall at a minimum meet the requirements of UL217, NFPA72, (chapter 11), The State of California Fire Marshall, NFPA 101 (One and two family dwellings) Federal Housing Authority (FHA), Housing and Urban Development (HUD). It shall also include a 10-year manufacture’s limited warranty.
Ordering Information
Model Number: | i12040 | |||||||||||||||
UPC: | 0-47871-40381-3 | |||||||||||||||
Power Source: | 120VAC (80mA) with 9V Battery Back Up | |||||||||||||||
Sensor: | Ionization | |||||||||||||||
Audio Alarm: | 85dB at 10ft | |||||||||||||||
Temperature Range: | 40˚F (4.4˚C) to 100˚F (37.8˚C) | |||||||||||||||
Humidity Range: | 5%-95% relative humidity (RH) | |||||||||||||||
Size: | 5.6” in diameter x 1.55” depth | |||||||||||||||
Weight: | .5lb | |||||||||||||||
Interconnects: | Up to 24 Kidde devices | |||||||||||||||
Wiring: | Quick-connect plug with 8” pigtails | |||||||||||||||
LED: | Red, 4 modes of operation | |||||||||||||||
Green, indicates AC power | ||||||||||||||||
Warranty: | 10 year limited |
Ordering | Dimensions | Case/ | Layers/ | Skid | |||||
Number | UPC | I2F5 | Pack Quantity | (w x d x h inches) | Weight | Skid | Skid | Weight | |
N/A | 0-47871-40381-3 | N/A | individual* | 5.75 x 1.5 x 5.75 | 0.5 lbs | N/A | N/A | N/A | |
21006378 | 0-47871-40381-3 | 100-47871-40381-0 | Cut Case (6 units) | 6.5 x 13.25 x 6 | 3 lbs | 147 | 7 | 441 lbs | |
21006373 | 0-47871-09970-2 | 200-47871-09970-2 | Bulk Pack (6 units) | 6 x 10.5 x 6 | 3 lbs | 147 | 7 | 441 lbs | |
21006930 International 806 manual download. | 0-47871-40381-3 | 300-47871-40381-4 | Display Pallet (36 units) | 20 x 24 x 40 | 20lbs | 4 | 1 | 90 lbs | |
Alk. Btry 21006928 | 0-25417-12751-5 | 100-25417-12751-2 | Cut Case (6 units) | 6.5 x 13.25 x 6 | 3 lbs | 147 | 7 | 441 lbs | |
Lith. Btry 21006929 | 0-25417-01276-7 | 100-25417-01276-4 | Cut Case (6 units) | 6.5 x 13.25 x 6 | 3 lbs | 147 | 7 | 441 lbs | |
21006375** | 0-47871-27552-6 | 100-47871-27552-3 | Cut Case (6 units) | 6.5 x 13.25 x 6 | 3 lbs | 147 | 7 | 441 lbs | |
21006372** | 0-47871-09969-9 100-47871-09969-3 | Cut Case (3 Twin Packs) | 6.5 x 13.25 x 6 | 3 lbs | 147 | 7 | 441 lbs | ||
*Not for sale by individual unit | **Includes Wiring Adapters |
Distributed by:
1016 Corporate Park Drive
Kidde Ionization Smoke Alarm Model I12020
Mebane NC 27302 1-800-880-6788 www.Kidde.com
Kidde Ionization Smoke Alarm Model I12020 User Manual Pdf
To continue the download you need to go through the captcha: